Accessoires:
Aucun
Accessoires inclus:
Aucun
Affichage:
LCD, 3.5 inch digit measurement readout and six-character alphanumeric scrolling text line
Alarme:
Two alarms selectable for sample concentration alarm, analyser system warning, or analyser system shut-down alarm. Each is equipped with an SPDT relay with contacts rated for 5A resistive load at 230 V AC.
Alimentation (tension):
100 - 115/230 V CA
Alimentation électrique (Amps):
2,5 A
Boîtier :
ABS plastic, two clear polycarbonate windows, IP62-rated with the gasketed door latched.
Caractéristique électrique (Hz):
50/60 Hz
Contenu de la boîte:
CL17 Chlorine Analyser with 1 Month Supply of Total Chlorine Reagents, Maintenance kit, Installation Kit, and Manual. (The power cord is ordered separately.)
Débit d'échantillonnage:
200 à 500 mL par minute minimum
Débit de l'échantillon:
200 à 500 mL par minute minimum
Description:
CL17 Chlorine Analyzer with Reagents for Total Chlorine
Durée d'analyse:
2.5 min
Entrée:
¼" OD polyethylene tube, quick-disconnect fitting
Garantie:
24 mois
Humidité de fonctionnement:
Up to 90 % at 40 °C (104 °F) maximum
Inclus:
CL17 Chlorine Analyser with 1 Month Supply of Total Chlorine Reagents, Maintenance kit, Installation Kit, and Manual. (The power cord is ordered separately.)
Interférences:
Other oxidizing agents such as bromide, chlorine dioxide, permanganate and ozone will cause a positive interference. Hexavalent chromium will cause a positive interference:
1 mg/L Cr6+ = approximately 0.02 mg/L as Cl2.
Hardness must not exceed 1,000 mg/L CaCO3.
Limite de détection:
0.03 mg/L (ppm)
Montage:
Wall mount
Moyens de communication:
4-20 mA output
Paramètres:
Chlorine, Free & Total
Plage de mesure:
0 - 5 mg/L Cl₂
Plage de pression:
Inlet Pressure to Sample Conditioning: 1.5 - 75 psi (0.1 - 5.2 bar)
Plage de température:
5 - 40 °C
Poids:
11,3 kg
Précision:
± 5 % or ±0,03 mg/L (ppm) as CL2, la valeur la plus grande
Pression d'entrée:
1 to 5 psi (0.07 - 0.34 bar), 1.5 psi (0.103 bar) is optimum
Pressure Regulator Included?:
No
Purge d'air:
0.1 cfm (0.17 m³/h) instrument quality air at max. 20 psi (ca.1.4 bar) with ¼" OD tube, quick disconnect fitting
Répétabilité:
0.01 ppm ou 3.0 % La valeur la plus grande
Sorties d’enregistreur:
Une sortie 0/4 - 20 mA programmable sur l’échelle de la gamme allant de 0 à 5 mg/L. Impédance de charge recommandée 3,6 à 500 ohms, 130 V avec isolement par rapport à la terre.
Source de lumière:
Class 1 LED (light emitting diode) with a peak wavelength of 520 nm; 50,000 hours estimated minimum life
Température de l'échantillon:
5 - 40 °C (41 - 104 °F)